6-117
DVST Digital Video Signal Type
Classification: Format parameter setting
Command Syntax: DVST <type>
Limits: <type>
0 = not used
1 = digital V
2 = digital VI (MDA)
5 = RGB
6 = RGBI (CGA)
7 = RrGgBb (EGA)
DVST must be zero (0) when any analog video type is
selected (AVST 0).
Query Syntax: DVST?
Query Response: <type>
Description: The DVST command establishes the kind of video signal that
exits the digital video signal outputs of the generator. The DVST?
query returns the current setting of DVST.
Note Please note that digital video is not supported by all
generators in the 801G series.
Other Required Cmds: AVST must be set to zero. The ALLU command updates the
hardware to the new setting and redraws the test image.
Example: AVST 0 // Deselect analog video in
// buffer
DVST 5 // Select 3 bit color in buffer
FMTU // Update hardware to current
// buffer contents